V-Cone Flow Sensor — BF30

BF30 V-Cone is a high-accuracy flow sensor for a wide range of media and service conditions, covering Reynolds numbers from 8×10³ to 5×10⁶. The cone element re-rectifies the velocity profile and creates a stable low-pressure zone immediately downstream, giving short straight-run requirements and a wide turndown.

Specifications

Accuracy0.5
Repeatability0.15
Turndown10:1 typical
Beta ratio (β)0.450 – 0.850
Reynolds range8×10³ – 5×10⁶
Straight run0–3D upstream / 0–1D downstream
FormsIn-line DN15–2000; wafer DN15–150; insertion DN150–2000+

Details

Working Principle

A sharp-apux cone is suspended coaxially in the measuring tube. The cone re-rectifies the velocity profile; a low-pressure zone forms immediately downstream of the cone (negative tap at the cone centre-axis end face), while the high-pressure static tap sits on the tube wall upstream before the flow contracts. The ΔP between the two is converted to flow via the Bernoulli equation. The leading edge of the cone is a sharp angle giving a smooth transition into the low-pressure region.

Key Features

  • Short straight-run: 0–3D upstream, 0–1D downstream
  • Long-term stability: β constant, no recalibration
  • Stable signal, low noise, low permanent pressure loss, no stagnant zones
  • Wide β range 0.450–0.850 and Reynolds range 8×10³–5×10⁶
  • Pipe (DN15–2000), wafer (DN15–150) and insertion (DN150–2000+) forms

Applications

Gas, steam & liquidHigh-pressure / high-temp serviceDirty mediaWide-turndown energy meteringLarge line sizes
MOQ
1 unit
Lead Time
1–4 units: 20–30 days
Packaging
Wooden case
Warranty
12 months
Certification
CE

Request a Quote