Measuring Compressed Air: Which Meter to Pick
Boka Engineering · 6 min read
Tags:airthermalutilities
Measuring Compressed Air: Which Meter to Pick
Why measure compressed air
Compressed air is one of the most expensive utilities in a plant — typically 10–20% of electricity. Metering each compressor, dryer and key user shows leaks and lets you charge cost centers fairly.
Three approaches compared
| Feature | Thermal mass | Vortex | DP/orifice |
|---|---|---|---|
| Accuracy | ±1.5% of reading + range | ±1.5–2% | ±1.5–3% |
| Pressure loss | Low | Low | Moderate |
| Needs compensation | No | Yes (add PT) | Yes (PT) |
| Sensitivity to oil/moisture | High (probe coating) | Low | Low |
Recommendations
- At the compressor discharge and dryers: thermal mass meters give direct standard flow, but keep them in a clean, dry spot.
- In distribution headers and large consumers: vortex with pressure compensation is accurate and immune to the oil present in older networks.
- Small branches and leak surveys: clamp-on ultrasonic is convenient when you cannot cut the line.
Installation notes
Give 10D upstream straight pipe and avoid fitting meters right after dryers where flow pulses. A monthly trend of each header helps quantify leak loss.