Metal-Tube Rotameter Selection Guide
Boka Engineering · 5 min read
Tags:variable-arearotameterpurge
Metal-Tube Rotameter Selection Guide
Ideal applications
- Purge and seal air, sampling and analyzer feed lines
- High pressure and temperature duties where glass would fail
- Small-bore lines from DN15 to DN100 with modest accuracy needs
Three sizing rules
- Keep the operating float position in the middle third of the tube for best readability.
- Confirm the fluid's density and viscosity at operating conditions — a rotameter is density-sensitive.
- For gas meters, verify the maximum flow at working pressure is within range.
Where rotameters fail
- Pulsating flow from reciprocating pumps causes float bouncing
- Solids or dirty media clog the annular gap
- Dusty gas may coat the tube and make the scale unreadable
Options that add value
- Magnetic or reed switch alarm contacts for low/high flow trips
- 4–20 mA output with alarm for remote control rooms
- PTFE-lined versions or Hastelloy floats for corrosive chemicals
- Fall-safe variants for loss of flow detection on seal lines
Ask for our sizing sheet — send fluid, pressure, temperature and the flow range and we reply with a model and price within a day.
Related Articles
8/22/2026
Electromagnetic Meter Grounding: The 5-Step Checklist
Why grounding is the most common cause of noisy magnetic meter readings.
5 min read
8/19/2026
Flow Meter Communication Protocols Explained
Choosing between 4-20 mA, HART, pulse, RS485/Modbus and Fieldbus for your system.
5 min read
8/15/2026
Clamp-On Ultrasonic vs Inline Meters: Which to Choose?
A practical comparison covering cost, accuracy, installation and straight-pipe needs.
6 min read
Need help choosing a flow meter?
Talk to our engineers for sizing
Contact